Tests for HIV Diagnosis

If you're worried that you might have been exposed to human immunodeficiency virus (HIV) -- the virus that causes AIDS -- it's important to get tested as soon as possible. Although the prospect of being diagnosed with the disease can be scary, today you can live a long and full life with HIV, especially if you start treatment early. Knowing you are infected can also help you take precautions so that you don't pass the virus to other people.
Several different tests are used to diagnose HIV infection. Other tests are used to select and monitor treatments in people who are living with HIV.
If you are infected with the HIV virus, your body will start to produce infection-fighting proteins against the virus, called antibodies. HIV antibody tests look for these proteins in your blood or other body fluids.
The most common HIV test, the enzyme-linked immunosorbent assay, or ELISA (also called EIA), is used to detect HIV antibodies in a sample of your blood. The device for test is microplate reader. Other versions of the antibody HIV test use a sample of saliva or urine.
Although HIV tests are very sensitive, they can produce false-positive results. So ELISA HIV tests must be confirmed with another HIV test, such as a Western blot or indirect immunofluorescence assay (IFA).
Antibodies won't show up in your blood or body fluid immediately after you've been infected. There is a "window period" of six to 12 weeks, and sometimes several months, before your body starts producing antibodies to the virus. So even if you tested negative within a few weeks of being exposed to HIV, you should get tested again at three months and six months.
Important note: The HIV virus is transmissible during the window period, even though the test may come back as negative.

2011年12月27日星期二

Mobile c arm system in Perlong Medical : PLX7000B High Frequency Mobile c arm system

Usage  of  c arm  system :
It is widely used in orthopedics, urology surgery, spinal surgery, abdominal , pain management , cardiology dept ,digestive department, gynecology and obstetrics and so on.

Techinical Parameters of c arm x ray system :

Item
Contents 
Output power
12KW 
Dual-focus 
small focus: 0.3
large focus :0.6
Inveter Frequency
60KHZ
Thermal Capacity
1000KJ 


Feature of  c arm  system
1. High power micro focus high frequency generator, optimize digital image
2. The domestic leading level overall pulse fluoroscopy, intellective exposure control, achieve ultra-low radiation dose
3. Multiple working modes, meet different clinical necessity
4. Leafy and vertical shadow control, reduce soft x-ray and skin dose effectively.
5. Imported image intensifier, digital CCD camera, provide high resolution image
6.Two high resolution LCD monitors, ensure the quality of image
7. The digital station is standard configured with DICOM 3.0 interface which makes it easy to connect to the internet. This system supports worklist and manual registration.
8. The work station has high-capacity digital storage function. Fluoroscopy and digital spot film can be lossless stored in digitized form, and it also has functions such as edge enhancement, multiple mirror image, gamma correction, cine loop, window width &window level, expert template and CD writer.
9. Four-dimensional electric motor control can position accurately and move smartly. The super large body frame provides commodious diagnostic space and more comfortable operation environment. The brand-new design and idea bring you transcendental experience.